20CQ-12CQ磁力泵
产品简介
详细信息
cq型磁力驱动泵结构简图
1泵壳2静环3动环4叶轮5密封圈6隔板7隔离套
8外磁钢总成9内磁钢总成10泵轴11轴套12联接架13电机14
cq型磁力驱动泵安装尺寸表
型号abcdefghjakmn机座螺孔pp11φφ管子连接
08cq-26348455538200105451584802416φ6------
10cq-36348455538200105451584802416φ6------
14cq-59071951075327012056161301303718φ7------
16cq-89070801255532016065181151404022φ11------
20cq-121008010513059.534016073181301606526φ12------
25cq-15125100140189.567.546020590-16024071.5-φ1275651009012010法兰连接
32cq-15125100140189.567.546020590-16024071.5-φ1290751201001210
32cq-25125100140189.567.546023090-16026085-φ1290751201001210
40cq-2014012015523575545220100-18029078.5-φ12100901301201414
40cq-3219014019027180620260112-24533691-φ12100901301201414
50cq-2519014019027180620260112-24533691-φ121101001401301414
50cq-4019014019027180620260112-24533691-φ121101001401301414
65cq-2521614020030590695300132-28035091-φ121301101601401414
65cq-3521614020036076720292120-28035090-φ121301101601401414
80cq-35254210---890160-----φ12----1414
80cq-50254210---890160-----φ12----1414
安装和使用1、磁力驱动泵应水平安装,不宜竖立,塑料泵体不得承受管路重量,对于特殊要求垂直安装的场合,电机务必朝上。
2、当抽吸液面高于泵轴心线时,起动前打开吸入管道阀门即可,若抽吸液面低于泵轴心线时,管道需配备底阀。
3、磁力驱动泵使用前应进行检查,电机风叶转动要灵活,无卡住无异常声响,各紧固件要紧固。4、检查电机旋转方向是否与磁力泵转向标记*。
5、电机启动后,缓慢打开排出阀,待泵进入正常工作状态后,再将排出阀调到所需开度。
6、磁力驱动泵停止工作前,应先关闭排出阀门,然后关闭吸入管阀门。
cq型磁力驱动泵使用注意事项
1、因磁力泵轴承的冷却和润滑是靠被输送的介质,所以禁止空动转,同时避免在工作中途停电后再启动时所造成时空载运转。
2、被输送介质中,若含有固体颗粒,泵入口要加过滤网:如含有铁磁质微粒,需加磁性过滤器。
3、泵在使用中环境温度应小于40℃,电机温升不得超过75℃。
4、被输送的介质及其温度应在泵材允许范围内(详见附表)。工程塑料泵的使用温度<60℃,金属泵的使用温度<100℃,输送吸入压力不大于0.2mpa,zui大工作压力1.6mpa、密度不大于1600kg/m3,粒度不大于30×10-6m2/s的不含硬颗粒和纤维的液体。
5、对于输送液为易沉淀结晶的介质,使用后应及时清洗,排净泵内积液。6、磁力驱动泵运行500小时后,应拆检轴承和端面动环的磨损情况,若轴承和轴套的间隙大于0.5~1mm,叶轮轴向窜动1.5~2mm时,应更换轴承和轴向动环。