品牌
生产厂家厂商性质
温州市所在地
流量 | 扬程 | 出口直径 | 电机功率 | 转 速 | 液下长度 | |
m3/h | m | mm | kw | r/min | m | |
25FYS-10 | 1.5 | 10 | 20 | 1.5 | 2900 | 300 至 2500 |
25FYS-18 | 3.6 | 18 | 20 | 2.2 | 2900 | |
40FYS-15 | 5 | 15 | 32 | 3 | 2900 | |
40FYS-20 | 10 | 20 | 32 | 3 | 2900 | |
40FYS-30 | 10 | 30 | 32 | 4 | 2900 | |
40FYS-40 | 10 | 40 | 32 | 5.5 | 2900 | |
50FYS-20 | 15 | 20 | 40 | 3 | 2900 | |
50FYS-25 | 15 | 25 | 40 | 4 | 2900 | |
50FYS-30 | 15 | 30 | 40 | 5.5 | 2900 | |
50FYS-40 | 15 | 40 | 32 | 7.5 | 2900 | |
50FYS-50 | 15 | 50 | 32 | 7.5 | 2900 | |
65FYS-32 | 29 | 32 | 50 | 11 | 2900 | |
65FYS-40 | 29 | 40 | 40 | 11 | 2900 | |
80FYS-20 | 50 | 20 | 65 | 11 | 2900 | |
80FYS-30 | 50 | 30 | 65 | 15 | 2900 | |
80FYS-34 | 50 | 34 | 65 | 15 | 2900 | |
80FYS-40 | 50 | 40 | 50 | 18.5 | 2900 | |
100FYS-32 | 100 | 32 | 80 | 22 | 2900 | |
100FYS-40 | 100 | 40 | 80 | 22 | 2900 | |
50FYS-50 | 7.5 | 12.5 | 32 | 2.2 | 1450 | |
65FYS-40 | 14.5 | 10 | 40 | 3 | 1450 | |
80FYS-40 | 25 | 10 | 50 | 4 | 1450 | |
100FYS-40 | 50 | 10 | 80 | 5.5 | 1450 |
■四、FYS型耐腐蚀液下泵使用注意事项
拆卸与装配
1、如更换或检查叶轮,可关闭出阀门,卸去法兰连接螺栓和底板连接螺栓,用起重工具将泵吊出容器。
2、将底板垂直在固定的支架上,卸去泵体的所有螺栓,取出泵盖和叶轮螺母,用双锤轻击泵体,即可卸下叶轮。
3、更换流动轴承则底板不动,只要卸去电机及相应支架,卸去泵联轴器、压盖、圆螺母,取也轴套体。
4、装配与拆卸的次序相反,注意轴上配件的同心度。
安装、使用、维修
1、 泵组装后,盘动联轴器,看是否转动灵活。检查是否有金属摩擦声,各部件螺母是否旋紧。
2、 检查泵轴和电机轴的同心度,上下联轴器外圆左右差数不得超过0.1mm,联轴器端面间隙保持1~2.5mm。
3、 泵的吸入口到容器底部之间距离为吸入口径的2~3倍。泵体与器壁距离应大于口径的2.5倍。
4、 泵的出液管路,应另设支架支撑,其重量不允许支撑在泵上。
5、 检查电机的旋转方向,使泵的旋转方向符合指示方向。
6、 关闭出口管路上的闸阀,接通冷却水管。
7、 超动电机,慢慢开启出口管闸阀到需要的位置,投入正常运转。
8、 经常检查泵与电机的情况,轴承温升不应超过75℃,轴承盒内应加足够黄油